Read across your air-temperature row to your relative-humidity column. On small screens, scroll the chart sideways to see every RH level.
How to read this dew point chart
- Find the air temperature. Use the temperature measured by your room sensor, not the temperature of the window or wall.
- Find the relative humidity. RH is the percentage shown by your hygrometer. Follow that column down to the matching temperature row.
- Compare the dew point with a measured surface. The cell gives a temperature in °C. Condensation is possible where the surface reaches or falls below that temperature.
For example, follow the 20°C row to the 60% RH column: the calculated dew point is 12.0°C. A 10°C window surface is below that value even though the room air is warm.
If your readings fall between the listed rows or columns, do not treat a neighbouring cell as an exact answer. Use the free dew point calculator for your temperature, RH and measured surface, in Celsius or Fahrenheit. No contact details are required.
20°C air · 40% RH · 10°C surface
6.0°C dew point
The surface is 4.0°C above the dew point.
This measured surface is above the calculated dew point. Condensation is not predicted at this spot under these air conditions; other surfaces or later readings may differ.
20°C air · 60% RH · 10°C surface
12.0°C dew point
The surface is 2.0°C below the dew point.
This measured surface is below the calculated dew point. Condensation is possible at this spot under these air conditions; the calculation does not identify the cause of a damp problem.
The two examples use the same room and surface temperatures to show what changes when RH rises. They are worked comparisons, not measurements of your home or universal humidity targets. A surface above the dew point is not proof that the home is free from damp or mould. Persistent damp, visible mould or signs of a leak need investigation, not just a different humidity setting.
Reading guide reviewed 7 October 2026. Reference grid unchanged from 20 September 2026.